Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-103-5095

5925-00-103-5095, 5925001035095 NSN Information

Request for Quote

Manufacturer Part Number(s):555260-036, M39019/03-79, MIL-C-39019/3, SM33-20-240-400-2

FSC NIIN ITEM NAME
5925 001035095 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-103-5095 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
555260-036 BAE SYSTEMS NATIONAL SECURITY 12436 C 1 E D
M39019/03-79 MILITARY SPECIFICATIONS 81349 2 2 E
MIL-C-39019/3 MILITARY SPECIFICATIONS 81349 4 1 E
SM33-20-240-400-2 EATON CORP 74193 C 1 E D

5925-00-103-5095 Characteristics

MRC Requirement Statement Characteristics
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
ADAT BODY WIDTH 1.281 INCHES MAXIMUM
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CQJX NOMINAL THREAD SIZE 0.375 INCHES
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC ALL LOCATIONS
SR-1 SPEC/STD CONTROLLING DATA
SR-1 DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39019/03-79
ADTV CASE MATERIAL METAL
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
THSD THREAD SERIES DESIGNATOR UNEF
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
CPRQ RESET METHOD MANUAL
SR-1 NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-39019/3
ABXD BUSHING LENGTH 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
BBRJ III SPECIAL HANDLING FEATURE MAGNETIC
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-39019/3 GOVERNMENT SPECIFICATION
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
ADAQ BODY LENGTH 1.562 INCHES MAXIMUM
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
SR-1 MANUFACTURERS CODE 81349
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CMLP THREAD QUANTITY PER INCH 32
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AKPX POLE QUANTITY 2
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HERMETICALLY SEALED
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS