| MRC |
Requirement Statement |
Characteristics |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| ASDB |
WIDTH ACROSS FLATS |
0.875 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
240.0 AC AT SEA LEVEL FIRST VOLTAGE 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
| AAJD |
THREAD CLASS |
2A SINGLE THREADED BUSHING |
| CTYX |
CONTACT STIMULUS RATING |
205.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 215.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 190.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 200.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 15.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CMLP |
THREAD QUANTITY PER INCH |
14 SINGLE THREADED BUSHING |
| CSCF |
TERMINAL TYPE |
TAB W/SCREW |
| ADAQ |
BODY LENGTH |
1.885 INCHES NOMINAL |
| CQJX |
NOMINAL THREAD SIZE |
0.500 INCHES SINGLE THREADED BUSHING |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| ABPM |
BODY DIAMETER |
0.545 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
PTF-SAE SHORT SINGLE THREADED BUSHING |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL W/FLANGE |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| ABHP |
OVERALL LENGTH |
2.610 INCHES NOMINAL |
| AASA |
THREAD LENGTH |
0.750 INCHES NOMINAL SINGLE THREADED BUSHING |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| AKBY |
TEMP SENSING ELEMENT TYPE |
BULB |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE 60.0 SECOND VOLTAGE |