Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-062-3354

5925-00-062-3354, 5925000623354 NSN Information

Request for Quote

Manufacturer Part Number(s):3XAM17-2-5-208-400-55, DMS 83059B, S271MS183P002

FSC NIIN ITEM NAME
5925 000623354 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-062-3354 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
3XAM17-2-5-208-400-55 EATON CORP 74193 5 9 2
DMS 83059B DLA LAND AND MARITIME 16236 5 9 2
S271MS183P002 RAYTHEON ELECTRONIC SYSTEMS INC 04164 3 2 2
S271MS183P002 RAYTHEON TECHNICAL SERVICES COMPANY 3B150 5 2 2
S271MS183P002 RAYTHEON COMPANY 49956 5 9 2

5925-00-062-3354 Characteristics

MRC Requirement Statement Characteristics
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.5 AMPERES AC ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 6 SCREW
SR-5 MANUFACTURERS CODE 04164
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT AND 8.500 MAXIMUM AT 200 PCT ALL LOCATIONS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.812 INCHES NOMINAL
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED EXPLOSION RESISTANT
ADAT BODY WIDTH 2.273 INCHES NOMINAL
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRQ RESET METHOD MANUAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3500.0 AC ALL LOCATIONS
SR-5 THE MANUFACTURERS DATA
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.000 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
THSD THREAD SERIES DESIGNATOR UNC
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 208.0 AC ALL LOCATIONS
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
CMLP THREAD QUANTITY PER INCH 32
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 10.000 MINIMUM AND 30.000 MAXIMUM ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AKPX POLE QUANTITY 3
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ADAQ BODY LENGTH 2.500 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.190 INCHES NOMINAL
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
SR-5 DESIGN CONTROL REFERENCE S271MS183P002