| MRC |
Requirement Statement |
Characteristics |
| AXGY |
MOUNTING METHOD |
BRACKET |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
3.281 INCHES NOMINAL |
| CMLP |
THREAD QUANTITY PER INCH |
28 SINGLE PRESSURE CONNECTION |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL ACTUATION POINT SCREW |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE PRESSURE CONNECTION |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
550.0 AC AT SEA LEVEL FIRST VOLTAGE 115.0 AC AT SEA LEVEL SECOND VOLTAGE 550.0 DC AT SEA LEVEL THIRD VOLTAGE 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE 13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE 4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| AFDT |
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
0.656 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
TAB W/SCREW |
| ABMK |
OVERALL WIDTH |
5.000 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| ABHP |
OVERALL LENGTH |
5.812 INCHES NOMINAL |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
2.406 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
2.688 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
2.750 INCHES NOMINAL |
| CTYM |
CONTACT ADJUSTMENT RANGE |
10.00 TO 180.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE 60.0 SECOND VOLTAGE |