Home > Switches > FSC 5930 > 5930-00-802-2557

5930-00-802-2557, 5930008022557 NSN Information

Request for Quote

Manufacturer Part Number(s):222-10NLM-2221605, 222-10NLM2221065

FSC NIIN ITEM NAME
5930 008022557 SWITCH,THERMOSTATIC
INC ESDC HMIC
0045 P

5930-00-802-2557 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
222-10NLM-2221605 DETROIT SWITCH INC. 19278 C 1 2 N
222-10NLM2221065 DETROIT SWITCH INC. 19278 3 2 2

5930-00-802-2557 Characteristics

MRC Requirement Statement Characteristics
MEDA MEDIA FOR WHICH DESIGNED GAS
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 550.0 AC AT SEA LEVEL SECOND VOLTAGE 115.0 DC AT SEA LEVEL THIRD VOLTAGE 550.0 DC AT SEA LEVEL FOURTH VOLTAGE
CQGB CONTACT ACTION STIMULUS INCREASE
AFDV LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 3.280 INCHES NOMINAL
AEVV BULB DIAMETER 0.688 INCHES NOMINAL
AEVU BULB LENGTH 8.250 INCHES NOMINAL
AKBY TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
ABHP OVERALL LENGTH 5.000 INCHES NOMINAL
CTYS CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.281 INCHES NOMINAL
AXGY MOUNTING METHOD BRACKET AND UNTHREADED HOLE
CSCF TERMINAL TYPE TAB W/SCREW
CTHF CONTACT LOAD CURRENT RATING 13.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 2.7 AMPERES RESISTIVE LOAD SECOND VOLTAGE 4.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE 1.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
PMLC III PRECIOUS MATERIAL AND LOCATION CONTACTS SILVER
ABMK OVERALL WIDTH 2.875 INCHES NOMINAL
ADAU BODY HEIGHT 2.750 INCHES NOMINAL
AWTN OPERATING TEMP RATING -100.0 DEG FAHRENHEIT MINIMUM AND 120.0 DEG FAHRENHEIT MAXIMUM
ABKW OVERALL HEIGHT 4.000 INCHES NOMINAL
STYL STYLE DESIGNATOR RECTANGULAR
AEVT CAPILLARY TUBE LENGTH 120.000 INCHES NOMINAL
AFDS LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 2.406 INCHES NOMINAL
PRMT III PRECIOUS MATERIAL SILVER
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CQYJ MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
ABFE III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION GENERAL PURPOSE-NEMA TYPE 1
AFDT SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 1.375 INCHES NOMINAL
CTYC CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CTYM CONTACT ADJUSTMENT RANGE 25.00 TO 90.00 ACTUATION POINT DEGREES FAHRENHEIT AND 23.00 TO 90.00 DEACTUATION POINT DEGREES FAHRENHEIT